Back to job search
Expand Reach Inc. logo

Fire Alarm Designer

  • Markham, ON
  • On-site
  • Posted Oct 4, 2026
  • 1 position

$65–$85 / year

Opens LinkedIn

Sign in to save this job
Employment type
Full-time
Experience level
Senior · 5+ years
Apply by
Nov 1, 2026
Posting language
English
Working hours
40 hours per week
Seniority
Associate
Application method
Direct apply is available

Job summary

Design code-compliant fire detection, gas monitoring, and suppression systems for heavy industrial facilities, and produce complete AutoCAD drawing and engineering packages. Coordinate system integration and project reviews, and lead or supervise factory and site acceptance testing as required.

Job details

Role and Responsibilities: System Design & Calculations: Design reliable, code-compliant fire detection, gas monitoring, and fire suppression systems tailored, as well as, develop system architectures and panel layouts for heavy industrial applications. Ensure all system architectures meet North American life safety standards and hazardous area compliance (Classified/Ex environments). Perform critical circuit and system calculations, including voltage drop, battery backup sizing, and loop capacity (NACs/SLCs). CAD & Engineering Deliverables: Utilize AutoCAD to produce complete Issued for Construction (IFC) drawing packages from initial concept through project completion. Develop Fire & Gas Piping & Instrumentation Diagrams (P&IDs), General Arrangement (GA) equipment layouts, and panel interior/exterior elevations. Create detailed point-to-point wiring schematics, terminal block diagrams, and interconnect schedules. Control Logic & System Integration: Prepare Cause & Effect (C&E) matrices and Functional Design Specifications (FDS) to outline system operations and emergency response logic. Coordinate auxiliary interlocks, including HVAC shutdown sequences, damper control, and Emergency Shutdown (ESD) interfaces. Project & Team Collaboration: Participate in in-person design reviews, hazard assessments (HAZOP/SIL), and client coordination meetings. Review vendor submittals, equipment specifications, and Bills of Materials (BOM). Partner directly on-site with Electrical, Instrumentation, Mechanical, Process, Production, Operations, and Engineering teams to ensure seamless intersystem coordination by verifying proper system programming, wiring accuracy, and testing completion. Lead and supervise Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) as required. Qualifications: Education: Diploma or Degree in Electrical Engineering Technology, Fire Protection Engineering, Drafting/Design, or a related discipline. Experience: 5+ years of dedicated fire alarm design experience, with at least 3 years focused on heavy industrial projects (e.g., Oil & Gas, thermal, hydro, or power generation facilities). Practical experience designing for hazardous locations (Class I, Div 1/2 or Zone 0/1/2) and intrinsically safe systems is preferred. Technical Software: Advanced mastery of AutoCAD (2D/3D). Experience with AutoCAD Electrical or MicroStation is considered a strong asset. Familiarity with 3D coordination environments (Navisworks, SmartPlant, PDMS) is preferred. System Familiarity: Strong working knowledge of major industrial fire alarm control panels, gas detection hardware, and safety controllers. Experience with Honeywell (Notifier and Scame Sistemi) and Johnson Controls (Autocall) is preferred. Codes & Standards: In-depth working knowledge of NFPA 72, CAN/ULC-S524, and relevant electrical codes (CEC/NEC). Professional Certification: Registered CFAA - Certified Fire Alarm Technician is preferred. If you believe you are a qualified candidate for this position and would like to pursue this opportunity, please apply to this position by sending your resume to alan.hung@expandreach.ca! For more information, please contact: Alan Hung, Recruitment Lead Expand Reach Inc. 905-415-8828 x5002

What you’ll do

Design code-compliant fire detection, gas monitoring, and suppression systems for heavy industrial facilities, and produce complete AutoCAD drawing and engineering packages. Coordinate system integration and project reviews, and lead or supervise factory and site acceptance testing as required.

Requirements

Requires a diploma or degree in electrical engineering technology, fire protection engineering, drafting/design, or a related discipline, plus at least five years of fire alarm design experience, including three years on heavy industrial projects. Requires advanced AutoCAD skills and knowledge of applicable life-safety codes; hazardous-location experience, specified system vendors, and CFAA certification are preferred.

Listed skills

  • AutoCAD · Preferred

Other relevant skills

Identified from the job description. Confirm important requirements above.

  • Fire Alarm System Design
  • Fire Detection Systems
  • Gas Detection Systems
  • Fire Suppression Systems
  • AutoCAD
  • Electrical Calculations
  • Hazardous Area Design
  • Fire Alarm Control Panels
  • P&ID Development
  • Wiring Schematics
  • Cause And Effect Matrices
  • Functional Design Specifications
  • System Integration
  • Factory Acceptance Testing
  • Site Acceptance Testing
  • NFPA 72

Job areas

  • Engineering
  • Security & Safety
  • Energy
  • Construction

More jobs from Expand Reach Inc.

See all jobs from Expand Reach Inc.